Skip to content
LIVING IN AND AROUND BANGALORE? CALL US @ +91 70221 98111 / +91 80502 00008, FOR SPECIAL PRICES
LIVING IN AND AROUND BANGALORE? CALL US @ +91 70221 98111 / +91 80502 00008, FOR SPECIAL PRICES

Lutron RF Relay Module with Softswitch (LMN-16R-DV-B)

by Lutron

RF Relay Module with Softswitch (LMN-16R-DV-B)

Compatible with RA2 Select, RadioRA 2, and HomeWorks systems

The RF relay module with Softswitch is a radio frequency (RF) device that uses Lutron patented Softswitch technology to control up to 16 A of general-purpose loads based on input from RA2 Select, RadioRA 2, and HomeWorks systems.

Features

  • Lutron patented Softswitch technology prevents arcing of relay contacts, extending product lifetime.

  • Various operating voltages available—refer to Models chart below for details on voltage requirements.

  • Capable of switching 16 A of general-purpose loads.

  • Utilizes Lutron Clear Connect RF technology—refer

    to Models chart below for frequency band data and

    Lutron system compatibility.

  • Mounts to an electrical junction box through a 1/2 in

    (21 mm trade-size) knockout opening.

  • Complies with requirements for use in a

    compartment handling environmental air (plenum) per NEC® 2011 300.22(C)(3) (LMJ- model only).

Specification

Power -

120/277 V~ 50/60 Hz 16 A 0.5 HP at 120 V~ 1.5 HP at 277 V~ (LMJ- model) 220–240 V~ 50 / 60 Hz 16 A motor: 6 A (LMK-, LMM-, LMN-, LMQ- models)

Typical Power Consumption - 

< 1.0 W
Typical power test conditions: all loads off, top LED on

Regulatory Approvals - 

UL®, UL 2043 Plenum Rated, FCC Approved. Complies with the limits for a Class B device, pursuant to Part 15 of the FCC rules:
CSA, IC, NOM, ANATEL (LMJ- model)
CE, TRA, CITC (LMK- model)

WPC (LMN- model)

Environment - 

Ambient operating temperature: 32 °F to 131 °F (0 °C to 55 °C) Ambient operating humidity: 0% to 90% humidity, non-condensing. Indoor use only.

Communications - 

Operates using Clear Connect RF technology for reliable wireless communication; refer to Models chart on page 1 for band frequency details. RF range is 30 ft (9 m) from repeaters. Contact Lutron for applications using foil-backed or metallic ceiling tiles.

Load - 

Maximum load: 16 A general purpose. No minimum load requirements.
Load types include, but are not limited to: Incandescent, MLV, ELV, Resistive, Inductive, Magnetic fluorescent, and Electronic fluorescent.

Surge Protection - 

Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits.

Mounting - 

Mounts to an electrical junction box through a 1/2 in (21 mm trade-size) knockout opening.